Varnish Removal System

HPSVR Varnish Removal System

Prevent varnish related servo valve failures on small gas turbines and compressor lube oil applications (ie gas transmission compressor units).

  • Remove & prevent varnish deposits with DCB element technology (Dried Ion Charge Bonding).

  • Achieve & maintain MPC value < 20 (lower varnish potential).

  • Lower ISO codes to 14/12/9 with high efficiency post filter element.

  • Extend life of anti-oxidant additives & prevent premature oil replacement.


DCB removes the soluble varnishing building oxidation by-products at the molecular level reversing the process of varnish deposits while BCA removes the gross insoluble by-products for a more rapid reduction in varnish potential.

微信图片_20190222142547.png

Suitable Operating Temperature Range
90°F/32°C (minimum) to 160°F/71°C (maximum)Operating below minimum can result in reduced acid and

metal ion removal efficiency

Warning: Do not operate above max temperature 160°F/71°C. Contact factory to add pre-cooler before DCB media (operating temp required).